HELIOS LED

Characteristics

Properties

Materials
White polycarbonate body,
Opal polycarbonate cover

Mounting
Surface

Power supply
Self contained - 220 - 240 VAC 50/60 Hz
Central battery CB - 220 - 240 VAC 50/60 Hz, 176 -275 VDC
Central battery FZLV II - 48 VDC
Central battery FZLV  - 24 VDC

Light source
1W, 2W LED
Colour temperature: 6000K
Lifetime: 50000h

Charging
Standard: max. 24h
Premium: max. 12h; energy-saving electronic charger

Autonomy
1 h or 3 h

Insulation class
II or III

IP & IK rating
IP42 or IP65, IK08

Viewing distance
25m

Viewing method
One- sided

Ambient temperature
Self- contained: ta: 0°C ÷ 40°C or ta: -25°C ÷ 40°C - together with heater for low temperatures
Central battery: ta: 0°C ÷ 50°C

Option
SE – non - maintained
SA – maintained
AT – autotest
PT – test button
RU – Rubic UNA central monitoring
RW – Rubic UNA Wireless central monitoring
RD - DALI central monitoring
FZLV – central battery FZLV 24 VDC
FZLV2 – central battery FZLV II 48VDC
CB – central battery

Additional information
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C with HTR 25
III class of insulation of FZLV and FZLV II version

Dimensions

Versions

Konfiguracja oprawy autonomicznej

CODE POWER MODULE AUTONOMY MODE OPTIONS
ECO LED HL 1.2W E 1 3 SE PT AT X
2W E 1 3 SE PT AT X
STANDARD HL 1.2W C 1 3 SE SA PT AT X
2W C 1 3 SE SA PT AT X
PREMIUM HL 1.2W B 1 3 SE SA AT RU RW
2W B 1 3 SE SA AT RU RW

Konfiguracja oprawy do centralnej baterii

CODE POWER MODULE SYSTEM OPTIONS
CB HL 1.2W F CB CBS X
2W F CB CBS X

Konfiguracja oprawy do centralnej baterii adresowalnej

CODE POWER MODULE SYSTEM OPTIONS
CB HL 1.2W Z CB ADE ADP
2W Z CB ADE ADP

Konfiguracja oprawy do centralnej baterii FZLV

CODE POWER SYSTEM
FZLV / FZLV II HL 1.2W FZLV FZLV2
2W FZLV FZLV2
ECO LED - self contained – 220 - 240VAC 50 - 60Hz
CB - central battery version CBS – 220 - 240VAC 50 - 60Hz; 176 - 275VDC
STANDARD - self contained – 220 - 240VAC 50 - 60Hz
PREMIUM - self contained – 220 - 240VAC 50 - 60Hz
2W - light source power 2W
F - electronic gear for central battery fittings
Z - electronic gear for addressable central battery fittings
C - electronic gear for STANDARD self-contained fittings
B - electronic gear for PREMIUM self-contained fittings
1 - autonomy 1 hour
3 - autonomy 3 hours
FZLV - central battery FZLV 24 VDC
FZLV2 - central battery FZLV II 48 VDC
SE - non maintained
SA - maintained
PT - manual test button
AT - autotest
X - fitting without additional options
CBS - central battery for circuit monitoring
ADE - address module for CBS 2.0 – SMART technology
ADP - address module for CBS 1.0 – SMART technology
RU - rubic UNA central monitoring
RW - Rubic UNA Wireless central monitoring

Configurator

Unable to generate PDF. Please try again later.

Files to download

Data sheet

pdf 0.73 MB

Kitemark

pdf 0.87 MB

Declaration of Conformity

pdf 0.39 MB

Certificate of Conformity

pdf 1.35 MB

User manual

pdf 3.49 MB