HELIOS DS LED

Characteristics

Properties

Materials
White polycarbonate body,
Opal polycarbonate cover

Mounting
Surface, 
Optionally wall or ceiling bracket

Power supply
Self contained - 220 - 240 VAC 50/60 Hz
Central battery CB - 220 - 240 VAC 50/60 Hz, 176 -275 VDC
Central battery FZLV II - 48 VDC

Light source
1W, 2W LED
Colour temperature: 6000K
Lifetime: 50000h

Charging
Standard: max. 24h
Premium: max. 12h; energy-saving electronic charger

Autonomy
1 h or 3 h

Insulation class
II or III

IP & IK rating
IP42 or IP65, IK08

Viewing distance
25m

Viewing method
Double- sided

Ambient temperature
Self- contained: ta: 0°C ÷ 40°C or ta: -25°C ÷ 40°C - together with heater for low temperatures
Central battery: ta: 0°C ÷ 50°C

Option
SE – non - maintained
SA – maintained
AT – autotest
PT – test button
RU – Rubic UNA central monitoring
RD - DALI central monitoring
RW2 – Rubic UNA Wireless central monitoring
BT - bluetooth
IT - NB-IoT
FZLV2 – central battery FZLV II 48VDC
CB – central battery

Additional information
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C with HTR 25
III class of insulation of FZLV II version

Dimensions

Versions

Self-contained configuration

CODE POWER MODULE AUTONOMY MODE OPTION COVER
STANDARD HDL
HDEL
1.2W E C 1 3 SE SA PT AT X OP
2W E C 1 3 SE SA PT AT X OP
PREMIUM HDL
HDEL
1.2W B 1 3 SE SA AT RU RD RW2 BT IT OP
2W B 1 3 SE SA AT RU RD RW2 BT IT OP

Central bettery configuration - non addressable

CODE POWER MODULE SYSTEM OPTION COVER
CB HDL
HDEL
1.2W F CB CBS X OP
2W F CB CBS X OP

Central bettery configuration - addressable

CODE POWER MODULE SYSTEM OPTION COVER
CB HDL
HDEL
1.2W Z CB ADE OP
2W Z CB ADE OP

FZLV system configuration

CODE POWER SYSTEM COVER
FZLV / FZLV II HDL
HDEL
1.2W FZLV2 OP
FZLV / FZLV II HDL
HDEL
2W FZLV2 OP
ECO LED - self contained – 220 - 240VAC 50 - 60Hz
CB - central battery version CBS – 220 - 240VAC 50 - 60Hz; 176 - 275VDC
STANDARD - self contained – 220 - 240VAC 50 - 60Hz
PREMIUM - self contained – 220 - 240VAC 50 - 60Hz
1.2W - light source power 1.2W
2W - light source power 2W
E - electronic gear for STANDARD self-contained fittings
F - electronic gear for central battery fittings
Z - electronic gear for addressable central battery fittings
C - electronic gear for STANDARD self-contained fittings
B - electronic gear for PREMIUM self-contained fittings
1 - autonomy 1 hour
3 - autonomy 3 hours
FZLV2 - central battery FZLV II 48 VDC
SE - non maintained
SA - maintained
PT - manual test button
AT - autotest
X - fitting without additional options
CBS - central battery for circuit monitoring
ADE - address module for CBS 2.0 – SMART technology
RU - rubic UNA central monitoring
RD - DALI central monitoring
RW2 - Rubic UNA Wireless central monitoring
BT - bluetooth
BT - black body, transparent cover
IT - NB-IoT
RW - Rubic UNA Wireless central monitoring
OP - opal polycarbonate cover

Configurator

Unable to generate PDF. Please try again later.

Files to download

Data Sheet

pdf 0.7 MB

Kitemark

pdf 0.87 MB

ENEC

pdf 0.91 MB

Declaration of Conformity

pdf 0.39 MB

Certificate of Conformity

pdf 1.35 MB

User Manual

pdf 1.73 MB